Description
Enclosed Mean Well switching power supply, 12 V / 8.5 A (102 W), with 85–264 V AC input, adjustable output and fanless cooling.
| Output voltage / current | 12 V / 8.5 A |
|---|---|
| Power | 102 W |
| Input voltage | 85–264 V AC |
| Output voltage adjustment | 10.2–13.8 V |
| Operating temperature | −30 to +70 °C |
| Dimensions | 129 × 97 × 30 mm |
Product description
LRS-100-12 · Mean Well
Enclosed Mean Well switching power supply, 12 V / 8.5 A (102 W), with 85–264 V AC input, adjustable output and fanless cooling.
The LRS-100-12 is a Mean Well LRS-100-series switching power supply in an enclosed perforated metal case only 30 mm high. It accepts 85–264 V AC (47–63 Hz) and delivers 12 V at up to 8.5 A, 102 W in total, for control panels, access controllers, cameras, locks and other 12 V loads. It does not charge a backup battery; for battery backup there are the SCP-series supplies.
A potentiometer sets the output between 10.2 and 13.8 V, for example to make up for voltage drop on long cable runs. Efficiency is typically 88%. It is cooled by free air convection with no fan and works from −30 to +70 °C (with load derating at high temperatures, per the maker's curve). An LED shows that the output is live.
It is protected against short circuit and overload (110–150% of rated power, hiccup mode with automatic recovery) and output over-voltage (13.8–16.2 V, output shut down, recovers when power is reapplied). It withstands a 300 V AC input surge for 5 s and a 5G vibration test. No-load consumption is below 0.3 W.
| 1 | 12 V / 8.5 A. Output power 102 W. |
|---|---|
| 2 | Input 85–264 V AC. Wide input range, also 120–373 V DC. |
| 3 | Adjustable output. From 10.2 to 13.8 V by potentiometer. |
| 4 | Protection. Short circuit, overload, output over-voltage. |
| 5 | Fanless. Free air convection cooling, −30 to +70 °C. |
| 6 | Power LED. Shows that the output is live. |
Technical specifications
LRS-100-12
| INPUT | |
|---|---|
| Input voltage | 85–264 V AC · 120–373 V DC |
| Frequency | 47–63 Hz |
| Input current (typ.) | 1.9 A at 115 V AC · 1.2 A at 230 V AC |
| Inrush current (typ.) | 50 A at 230 V AC (cold start) |
| Efficiency (typ.) | 88% |
| No-load consumption | Below 0.3 W |
| OUTPUT | |
| Output voltage / current | 12 V / 0–8.5 A |
| Rated power | 102 W |
| Output voltage adjustment | 10.2–13.8 V |
| Voltage tolerance | ±1.0% |
| Hold-up time (typ.) | 55 ms at 230 V AC, full load |
| Indicator | Power LED |
| PROTECTION | |
| Overload | 110–150% of rated power, hiccup, automatic recovery |
| Short circuit | Yes |
| Output over-voltage | 13.8–16.2 V, output shut down, recovers on re-power |
| Input surge | Withstands 300 V AC for 5 s |
| Isolation withstand voltage | Input–output 4 kV AC |
| Safety standards | UL 62368-1, EN 62368-1, EN 60335-1, EN 61558-1/-2-16 |
| MECHANICAL AND ENVIRONMENT | |
| Cooling | Free air convection, no fan |
| Operating temperature | −30 to +70 °C (with derating) |
| Operating humidity | 20–90% RH non-condensing |
| Vibration | 5G, 10–500 Hz |
| Dimensions (L × W × H) | 129 × 97 × 30 mm |
| Weight | 0.33 kg |
Documents
1 PDF file · English
| Type | TITLE | LANGUAGE | FORMAT | Open |
|---|---|---|---|---|
| DatasheetLRS-100-12 - Datasheet EN (2).pdf | English | PDF · 0.7 MB | Download the file Datasheet |