LRS-75-12 – Switching power supply 12 V / 6 A

Description

Product description

LRS-75-12 · Mean Well

Enclosed Mean Well switching power supply, 12 V / 6 A (72 W), with 85–264 V AC input, adjustable output and fanless cooling.

The LRS-75-12 is a Mean Well LRS-75-series switching power supply in an enclosed perforated metal case only 30 mm high. It accepts 85–264 V AC (47–63 Hz) and delivers 12 V at up to 6 A, 72 W in total, for control panels, access controllers, cameras, locks and other 12 V loads. It does not charge a backup battery; for battery backup there are the SCP-series supplies.

A potentiometer sets the output between 10.2 and 13.8 V, for example to make up for voltage drop on long cable runs. Efficiency is typically 89%. It is cooled by free air convection with no fan and works from −30 to +70 °C (with load derating at high temperatures, per the maker's curve). An LED shows that the output is live.

It is protected against short circuit and overload (110–150% of rated power, hiccup mode with automatic recovery) and output over-voltage (13.8–16.2 V, output shut down, recovers when power is reapplied). It withstands a 300 V AC input surge for 5 s and a 5G vibration test. No-load consumption is below 0.3 W.

STANDARD FUNCTIONS
112 V / 6 A. Output power 72 W.
2Input 85–264 V AC. Wide input range, also 120–373 V DC.
3Adjustable output. From 10.2 to 13.8 V by potentiometer.
4Protection. Short circuit, overload, output over-voltage.
5Fanless. Free air convection cooling, −30 to +70 °C.
6Power LED. Shows that the output is live.

Technical specifications

LRS-75-12

INPUT
Input voltage85–264 V AC · 120–373 V DC
Frequency47–63 Hz
Input current (typ.)1.4 A at 115 V AC · 0.85 A at 230 V AC
Inrush current (typ.)65 A at 230 V AC (cold start)
Efficiency (typ.)89%
No-load consumptionBelow 0.3 W
OUTPUT
Output voltage / current12 V / 0–6 A
Rated power72 W
Output voltage adjustment10.2–13.8 V
Voltage tolerance±1.0%
Hold-up time (typ.)60 ms at 230 V AC, full load
IndicatorPower LED
PROTECTION
Overload110–150% of rated power, hiccup, automatic recovery
Short circuitYes
Output over-voltage13.8–16.2 V, output shut down, recovers on re-power
Input surgeWithstands 300 V AC for 5 s
Isolation withstand voltageInput–output 4 kV AC
Safety standardsUL 62368-1, EN 62368-1, EN 60335-1, EN 61558-1/-2-16
MECHANICAL AND ENVIRONMENT
CoolingFree air convection, no fan
Operating temperature−30 to +70 °C (with derating)
Operating humidity20–90% RH non-condensing
Vibration5G, 10–500 Hz
Dimensions (L × W × H)99 × 97 × 30 mm
Weight0.23 kg

Documents

2 PDF files · English

TypeTITLELANGUAGEFORMATOpen
PDFDatasheetLRS-75-12 - Datasheet EN.pdfEnglishPDF · 0.7 MBDownload the file Datasheet
PDFDeclaration of conformityLRS-75-12 - CE declaration.pdfEnglishPDF · 0.5 MBDownload the file Declaration of conformity