SCP-75-12 – Backup (UPS) power supply 13.8 V / 5.4 A

Description

Product description

SCP-75-12 · Mean Well

Mean Well switching power supply with 12 V backup battery charging (UPS function), 13.8 V / 5.4 A (74.5 W) output and an AC OK / AC Fail signal.

The SCP-75-12 is a Mean Well SCP-75-series switching power supply for systems that must keep working without mains power, such as alarm control panels and access controllers. It powers the load at 13.8 V and at the same time charges a 12 V backup battery connected to the B+ / B− terminals. When mains power fails, the load runs from the battery.

Terminal L gives a mains status signal to the panel: with mains present (AC OK) it carries the output voltage plus 0.2–0.7 V, on mains failure (AC Fail) it drops to 0 V. An NTC thermistor (not included) can be connected to CN2 for temperature compensation of the charging voltage; without a sensor the charger works normally. A potentiometer sets the output from −5% to +15% (13.1–15.9 V).

It accepts 85–264 V AC and is protected against short circuit and overload (hiccup mode, automatic recovery), output over-voltage (16.6–19.3 V, output shut down) and reversed battery connection, by fuse. It works from −20 to +60 °C, with load derating at high temperatures.

STANDARD FUNCTIONS
1UPS function. Powers the load and charges a 12 V battery.
2AC OK / AC Fail signal. Tells the panel when mains power fails.
3Temperature compensation. Charging voltage via NTC thermistor (not included).
4Adjustable output. From −5% to +15% of the rated voltage.
5Protection. Short circuit, overload, over-voltage, reversed battery.
6Input 85–264 V AC. Wide input range, also 120–370 V DC.

Technical specifications

SCP-75-12

INPUT
Input voltage85–264 V AC · 120–370 V DC
Frequency47–63 Hz
Input current (typical)1.5 A at 115 V AC · 0.9 A at 230 V AC
Inrush current (typical)45 A (cold start)
Efficiency (typical)80%
OUTPUT
Output voltage / current13.8 V / 0–5.4 A
Peak current (5 s)6.5 A
Rated power74.5 W
Output voltage adjustment−5% to +15% (13.1–15.9 V)
Voltage tolerance±2.0%
Hold-up time (typical)50 ms at 230 V AC, full load
BATTERY AND SIGNALS
Battery12 V, on terminals B+ / B−
Temperature compensationNTC thermistor on CN2 (not included)
Mains status signal (L)AC OK: output voltage +0.2–0.7 V · AC Fail: 0 V
FusesInput F4A/250V (FS1) · battery F10A/250V (FS2)
PROTECTION
Overload6.5–8.7 A, hiccup, automatic recovery
Output over-voltage16.6–19.3 V, output shut down, recovers when power is reapplied
BatteryReversed connection, by fuse
Isolation withstand voltageInput–output 3 kV AC
Safety standardsUL 62368-1, CB (IEC 62368-1), EAC TP TC 004
MECHANICAL AND ENVIRONMENT
Operating temperature−20 to +60 °C (with derating)
Operating humidity20–90% RH non-condensing
Vibration2G, 10–500 Hz
Dimensions (L × W × H)159 × 97 × 38 mm
Weight0.5 kg

Documents

2 PDF files · English

TypeTITLELANGUAGEFORMATOpen
PDFDatasheetSCP-75-12 - Datasheet EN.pdfEnglishPDF · 0.6 MBDownload the file Datasheet
PDFDeclaration of conformitySCP-75-12 - Declaration of conformity EN.pdfEnglishPDF · 0.6 MBDownload the file Declaration of conformity