PIR motion detector with a volumetric lens and 12 m or 8 m coverage over 90°, set by the board position, with alarm memory and a bracket in the box.
| Technology | Dual-element PIR, microcontroller |
|---|---|
| Coverage | 12 m or 8 m, 90° angle |
| Supply | 8–15 V DC |
| Current | Max. 12 mA |
| Mounting height | 2.2–2.4 m |
| Bracket | Included |
Product description
ASTRA-517 · Teko
PIR motion detector with a volumetric lens and 12 m or 8 m coverage over 90°, set by the board position, with alarm memory and a bracket in the box.
The Astra-517 detects the change in heat radiation when a person crosses its detection zones, formed by a Fresnel lens and a dual-element pyroelectric sensor. The microcontroller processes the signal and opens the optoelectronic relay for 4 seconds on alarm. A cap with reflector on the pyroelectric sensor also creates a short-range zone.
The range is set by the position of the circuit board, which is held by a screw: in the lower position coverage is 12 × 12 m, in the upper position 8 × 8 m with denser zones. Jumpers select high or normal sensitivity (Sens), the LED (Ind) and alarm memory (Mem), which records violations and shows them on the LED.
It fits directly on a wall, in a corner or on the bracket supplied, at 2.2–2.4 m. The tamper opens the TMP contact when the cover is removed.
| 1 | Two ranges. 12 m or 8 m by board position. |
|---|---|
| 2 | Sensitivity setting. High or normal with the Sens jumper. |
| 3 | Alarm memory. Records violations, shown on the LED. |
| 4 | LED indication. Enabled or disabled with the Ind jumper. |
| 5 | Tamper. TMP contact that opens when the cover is removed. |
| 6 | Bracket. Included in the box. |
Technical specifications
ASTRA-517
| DETECTION | |
|---|---|
| Technology | Passive infrared (PIR), dual-element pyroelectric |
| Lens | Volumetric Fresnel, with short-range zone |
| Coverage | 12 × 12 m (lower board position) or 8 × 8 m (upper) |
| Angle | 90° |
| Movement speed | 0.3–3 m/s |
| Ambient light immunity | At least 6,500 lx |
| Sensitivity | High or normal (Sens) |
| OUTPUTS AND INDICATION | |
| Alarm relay | Optoelectronic, opens for 4 s, max. 80 mA / 100 V |
| Resistance in stand-by | Max. 8 Ω |
| Tamper | TMP contact |
| LED | Enabled with Ind, alarm memory with Mem |
| POWER | |
| Supply voltage | 8–15 V DC (12 V nominal) |
| Current | Max. 12 mA stand-by and alarm |
| Start-up time | Up to 60 s |
| MECHANICAL AND ENVIRONMENT | |
| Mounting | Wall, corner or bracket (included) |
| Mounting height | 2.2–2.4 m |
| Dimensions | 70 × 51 × 41 mm |
| Weight | Max. 50 g |
| Operating temperature | −30 to +50 °C |
| Relative humidity | Up to 98% at +25 °C, non-condensing |
| Manufacturer | TEKO (Russia) |
Documents
5 PDF files · English, Greek and Russian
| Type | TITLE | LANGUAGE | FORMAT | Open |
|---|---|---|---|---|
| ManualASTRA-517 - Manual EN.pdf | English | PDF · 0.8 MB | Download the file Manual | |
| ManualASTRA-517 - Manual RU.pdf | Russian | PDF · 1.0 MB | Download the file Manual | |
| CatalogueASTRA-517 - Catalogue EN.pdf | English | PDF · 25.8 MB | Download the file Catalogue | |
| ManualASTRA-517 - Manual GR.pdf | Greek | PDF · 1.3 MB | Download the file Manual | |
| Teko products brochureTeko - Products brochure.pdf | Greek | PDF · 3.7 MB | Download the file Teko products brochure |