Description
433 MHz SMART RF wireless module with 2 relay outputs that are programmed and used as Vision panel outputs, through the RF120 or RF121 receivers.
| Relays | 2, 1 A / 30 V DC |
|---|---|
| Frequency | 433.42 MHz, two-way |
| Receivers | RF120 / RF121 (version 2.51 or later) |
| Panel | Vision-X 2.53.18 or later |
| Supply | 9–28 V AC/DC, 70 mA at 12 V DC |
Product description
RF160 · Digiflex
433 MHz SMART RF wireless module with 2 relay outputs that are programmed and used as Vision panel outputs, through the RF120 or RF121 receivers.
The RF160 brings panel outputs to places cables cannot reach, for example a garage door or a gate. It talks two-way, with rolling-code encryption, to the RF120 or RF121 SMART RF receivers (version 2.51 or later), and each of its relays follows one panel output. You can use as many modules as you need, up to the panel's maximum number of outputs.
The outputs are set up on the panel like any other output (name, polarity, time), and the module is learned, tested or deleted from the RF devices menu; to learn it, hold both relay buttons on the module for 2 seconds. The RF Site Key locks the module to the site, so it cannot be learned onto another system. A Vision-X with firmware 2.53.18 or later is required.
The wide 9–28 V AC/DC supply (70 mA at 12 V DC) lets you power it from the door operator or another supply. The module mounts indoors, upright on a vertical surface, at least 30 cm from metal objects, and comes with an antenna. The RLY1 and RLY2 buttons operate the relays manually for testing.
| 1 | Wireless panel outputs. Each relay follows one panel output. |
|---|---|
| 2 | 2 relay outputs. 1 A / 30 V DC. |
| 3 | Two-way, encrypted. Rolling code, through RF120 or RF121. |
| 4 | RF Site Key. Locks the module to the site. |
| 5 | Wide supply range. 9–28 V AC/DC. |
| 6 | Test buttons. Manual operation of RLY1/RLY2. |
Technical specifications
RF160
| RADIO | |
|---|---|
| Frequency | 433.42 MHz, two-way |
| Security | Encrypted, rolling code, anti-substitution, RF Site Key |
| Compatible receivers | SMART RF RF120 and RF121, version 2.51 or later |
| OUTPUTS | |
| Relays | 2, 1 A / 30 V DC |
| Operation | Each relay follows one programmed panel output |
| Number of modules | Up to the panel's maximum number of outputs |
| COMPATIBILITY AND POWER | |
| Required panel | Vision-X, firmware 2.53.18 or later |
| Voltage | 9–28 V AC/DC |
| Current draw | 70 mA at 12 V DC |
| ENVIRONMENT AND MECHANICAL | |
| Operating temperature | 0–49 °C, indoors |
| Dimensions | 114 mm wide (128 mm with mounting tab) × 62 mm × 28 mm |
| Mounting | Vertical surface, portrait, at least 30 cm from metal |
| Included | Module, antenna, instruction sheet |
Documents
2 PDF files · English
| Type | TITLE | LANGUAGE | FORMAT | Open |
|---|---|---|---|---|
| Installation manualRF160 - Installation manual EN.pdf | English | PDF · 3.0 MB | Download the file Installation manual | |
| DatasheetRF160 - Datasheet EN.pdf | English | PDF · 2.2 MB | Download the file Datasheet |