SAM-24 – NOVA SMART SAM-24 module for glass and shutter contacts

Description

Product description

SAM-24 · Nova

NOVA SMART module fitted inside the alarm panel that lets you arm without bypassing zones, as long as either the glass or the shutter of each opening is closed.

The SAM-24 works with NOVA and NOVA SMART magnetic contacts. The glass and the shutter of each opening share one cable run but are monitored independently, and many openings go on one two-core cable. It suits new or existing systems, with no changes to the panel programming.

In Continuous Security each glass contact takes a 6.8 kΩ resistor in series and each shutter contact 4.7 kΩ; the two contacts of each opening are wired in parallel and the openings in series, up to 5 per zone. In Smart Management the glass contact takes 4.7 kΩ in series and the shutter contact is wired in parallel. In both cases the 4.7 kΩ end-of-line resistor is mandatory.

If the shutter is closed while the glass is open, the module bypasses the zone for 10 s; if the shutter is opened within that time, the bypass continues for the time set by jumper SW1 (5 minutes or unlimited). A foreign magnet held to the shutter reed is treated as tampering and opens the zone. Before connection to the panel, the module also works as a zone tester, with the zone on terminals 3 and 4 and a 12 V DC buzzer.

STANDARD FUNCTIONS
1Arm without bypass. Either the glass or the shutter of each opening just has to be closed.
2Glass and shutter on one cable. Each is still monitored independently.
3Two operating modes. Smart Management and Continuous Security.
4Tamper detection. A foreign magnet on the shutter reed opens the zone.
5Zone testing. The module works as a test tool before connection to the panel.
6No panel changes. For new or existing systems.

Technical specifications

SAM-24

GENERAL
TypeNOVA SMART module
MountingInside the alarm panel
Compatible contactsNOVA and NOVA SMART magnetic contacts
SystemsNew or existing, with no reprogramming
OPERATION
Operating modesSmart Management, Continuous Security
ArmingWithout bypassing zones, with glass or shutter closed at every opening
Openings per zoneUp to 5 (Continuous Security)
WiringGlass and shutter on the same two-core cable, monitored independently
Bypass time10 s, then 5 minutes or unlimited (jumper SW1)
IndicationZone status LED
TamperA foreign magnet on the shutter reed opens the zone
WIRING
Continuous Security, glass contact6.8 kΩ in series
Continuous Security, shutter contact4.7 kΩ in series
Smart Management, glass contact4.7 kΩ in series, shutter in parallel
End-of-line resistor4.7 kΩ, mandatory
Zone terminals3 and 4