Description
NOVA magnetic contact for opening aluminium, timber and PVC frames that fits inside the profile, normally closed (NC), in black.
| Application | Opening aluminium, timber and PVC frames |
|---|---|
| Fitting | Inside the frame cavities |
| Contact | Normally closed (NC) |
| Operating gap | 2 cm |
| Cable | 40 cm |
| Colour | Black |
Product description
MV-200 · Nova
NOVA magnetic contact for opening aluminium, timber and PVC frames that fits inside the profile, normally closed (NC), in black.
The MV-200 fits inside the frame cavities, so it is not visible and does not affect the look or operation of the frame. The magnet is screwed inside the profile cavity of the opening sash and the reed inside the chamber of the fixed frame. A sliding cover hides the fixing screw, the wiring and the cable entry hole.
Its shape suits many frame types, including difficult cases. If the window has a tilt (restrictor) function, NOVA recommends fitting at the bottom of the frame so that the alarm and the tilt function work together. Because fitting is specialised, installation is done by a trained installer.
The housing is polyamide PA6 and the magnet is neodymium (NdFeB). The switch handles up to 5 W and 60 V and connects to any conventional NC alarm zone through a 40 cm PVC cable, 0.14 mm².
| 1 | For opening frames. Aluminium, timber and PVC. |
|---|---|
| 2 | Concealed fitting. Magnet in the sash, reed in the frame chamber. |
| 3 | Sliding cover. Hides screw, wiring and cable hole. |
| 4 | Normally closed contact (NC). Connects to any conventional NC zone of an alarm panel. |
| 5 | With tilt function. Fit at the bottom of the frame. |
Technical specifications
MV-200
| GENERAL | |
|---|---|
| Type | Magnetic contact for opening frames |
| Application | Opening aluminium, timber and PVC frames |
| Fixing | Mechanical, screw-fixed, no adhesive |
| Colour | Black |
| ELECTRICAL | |
| Contact | Normally closed (NC) |
| Switched power | Up to 5 W |
| Switched voltage | Up to 60 V |
| Compliance | EMC Directive 2004/108/EC, EN 50130-4 |
| MECHANICAL | |
| Operating gap | 2 cm (guaranteed) |
| Housing | Polyamide PA6 |
| Magnet | Neodymium (NdFeB) |
| Wires | PVC, LiY 0.14 mm² |
| Operating temperature | −30 to +80 °C |
| Cable length | 40 cm |
Documents
2 PDF files · Greek
| Type | TITLE | LANGUAGE | FORMAT | Open |
|---|---|---|---|---|
| Declaration of conformityMV-200 - Declaration of conformity GR.pdf | Greek | PDF · 0.1 MB | Download the file Declaration of conformity | |
| EU design registrationMV-200 - EU design registration GR.pdf | Greek | PDF · 2.0 MB | Download the file EU design registration |