Description
Odytronics delay-on timer board (Delay ON) with a NO / C / NC relay output and 12 V DC supply.
| Function | Delay on (Delay ON) |
|---|---|
| Output | Relay NO / C / NC |
| Time setting | Linear potentiometer and jumper |
| Supply | 12 V DC |
| Protection | Reverse polarity |
Product description
PL-1002 · Odytronics
Odytronics delay-on timer board (Delay ON) with a NO / C / NC relay output and 12 V DC supply.
The PL-1002 (Time Delay and On) delays switching a load on. Timing starts the moment the board is powered; once the set time has elapsed, the relay energises. The relay releases when power is removed, and the board is ready for a new cycle.
The NO / C / NC changeover contact of the relay connects to the circuit you want to control. The time is set with a linear potentiometer; removing the jumper halves the time, which makes short delays easier to set. The board runs on 12 V DC and is protected against reverse-polarity connection.
The relay has 10 A contacts (250 V AC / 24 V DC). A red and a green LED show power and timing. Wires connect to lift-type terminals and the board sits on a flame-retardant PVC base with double-sided tape.
| 1 | Delay ON. The relay energises once the set time has elapsed after power-up. |
|---|---|
| 2 | Reset by removing power. The relay releases when the supply is cut. |
| 3 | NO / C / NC relay output. Changeover contact for the circuit you control. |
| 4 | Time setting. Linear potentiometer; removing the jumper halves the time. |
| 5 | Polarity protection. Protected against reverse-polarity connection of the supply. |
| 6 | LED indicators. Red and green LEDs for power and timing. |
Technical specifications
PL-1002
| OPERATION | |
|---|---|
| Type | Delay on (Delay ON) |
| Timing starts | When the board is powered |
| After the delay | The relay energises |
| Reset | The relay releases when power is removed |
| OUTPUT AND SETTING | |
| Output | Relay NO / C / NC |
| Relay contacts | 10 A (250 V AC / 24 V DC) |
| Time setting | Linear potentiometer |
| Jumper | Halves the time when removed |
| Indicators | Red and green LEDs (power, timing) |
| Terminals | Lift type |
| POWER | |
| Voltage | 12 V DC |
| Protection | Reverse polarity |
| CONSTRUCTION | |
| Base | Flame-retardant PVC, double-sided tape |