DIONE/WH – Dione Grade 3 self-powered outdoor siren, white housing, clear LED flash

Description

Product description

DIONE/WH · Sigma

Self-powered Grade 3 outdoor siren with a sound output of 122 dB at 1 m, clear LED flash and a white polycarbonate housing with an inner galvanised steel cover.

The siren is triggered by the panel when a positive or negative voltage is removed: the +TRIGGER input is balanced by a steady 8–12 V DC and alarms when that voltage is cut or drops below 5.0 V DC; the −TRIGGER input is balanced while it is connected to the panel negative. Only one of the two inputs is used. It follows the panel's alarm time, but also sounds if the wires are cut or short-circuited: 5 minutes if the +12 V supply is cut, 15 minutes if only the TRIGGER wire is cut. Each alarm starts at low volume for 10 seconds (pre-alarm / test mode) before rising to full level.

The flash has two high-brightness LEDs that blink alternately in stand-by and keep flashing for 15 minutes after the alarm ends, so the location is easy to find. The SIGN input shows arming and disarming for as long as it receives +12 V, with the flash only from the factory, or with flash and sound if JP2 is cut. The FLT OUT output (open collector) switches when the battery falls below 11.0 V, is disconnected or is faulty, and connects to an LED or a panel zone.

It takes a 12 V / 1.3 Ah lead-acid battery, not included. Charging stops above 13.8 V, the battery is protected against short circuit and reverse polarity, and without supply from the panel the siren will not sound with the battery below 10.0 V, so the battery is not damaged. Installation can be finished before the panel is connected: the siren starts working the first time the panel supplies voltage. Tamper on cover and wall, built-in spirit level on the base and IP44 protection.

STANDARD FUNCTIONS
1Trigger by voltage removal. +TRIGGER or −TRIGGER input, with an alarm also when the wires are cut or shorted.
2Pre-alarm / test mode. Low volume for the first 10 seconds of each alarm.
3LED flash. Blinks in stand-by and for 15 minutes after the alarm.
4SIGN input. Arm / disarm indication with flash, or flash and sound (JP2).
5FLT OUT output. Signal for low, disconnected or faulty battery.
6Double tamper. Volt-free contacts for cover opening and wall removal, to a 24-hour zone.

Technical specifications

DIONE/WH

SOUND AND FLASH
Sound output122 dB at 1 m
Operating frequency900–2,700 Hz
Maximum alarm time15 minutes
Flash2 high-brightness LEDs
Security gradeGrade 3
INPUTS AND OUTPUTS
+TRIGGERBalanced by 8–12 V DC, alarm when cut or below 5.0 V DC
−TRIGGERBalanced while connected to panel −, alarm when disconnected
SIGNArm / disarm indication on +12 V
FLT OUTOpen collector, below 11.0 V or battery disconnected / faulty, resets above 11.5 V
Cut wires5 minutes (supply or all), 15 minutes (TRIGGER only)
TamperCover and wall, NC-NO 600 mA / 125 V DC
POWER
Supply voltage13.2–14.5 V DC
Operating voltage13.8 V DC
Stand-by current13.0 mA with LEDs lit, 9.5 mA with LEDs off, 8 mA on battery only before first power-up
Alarm current1.2 A sound only, 1.35 A with flash
LED flash currentUp to 150 mA
BatteryLead-acid 12 V / 1.3 Ah (not included)
Battery protectionCharging stops above 13.8 V, short circuit, reverse polarity
Connection cable2 × 0.50 + 4 × 0.22 mm²
MECHANICAL
HousingPolycarbonate, inner galvanised steel cover
Housing colourWhite
Flash colourClear
Ingress protectionIP44
Dimensions190 × 290 × 65 mm (W × H × D)
Weight1,280 g (without battery)
Manufacturer code5041027

Documents

4 PDF files · English and Greek

TypeTITLELANGUAGEFORMATOpen
PDFBrochureDIONE-WH - Brochure EN.pdfEnglishPDF · 1.0 MBDownload the file Brochure
PDFCertificate Grade 3DIONE-WH - Certificate Grade 3.pdf—PDF · 1.5 MBDownload the file Certificate Grade 3
PDFManualDIONE-WH - Manual GR.pdfGreekPDF · 0.1 MBDownload the file Manual
PDFBrochureDIONE-WH - Brochure GR.pdfGreekPDF · 1.1 MBDownload the file Brochure