Description
Expansion board with 4 relay outputs (2 A / 24 V DC) for Digiflex Vision control panels, connected to the panel's RS485 bus.
| Outputs | 4 relays NO/NC/COM, 2 A @ 24 V DC |
|---|---|
| Connection | 4-wire RS485 bus |
| Distance | Up to 300 m or 1,200 m with Belden 8723 |
| Consumption | 30 mA, up to 200 mA with all relays on |
| Panels | Vision-X, Vision-XIP, MyAlarm-XIP (up to 8) |
Product description
CM710 · Digiflex
Expansion board with 4 relay outputs (2 A / 24 V DC) for Digiflex Vision control panels, connected to the panel's RS485 bus.
The CM710 adds 4 programmable Form C relay outputs to the control panel, with NO, NC and COM contacts, for LED indicators, garage doors, lighting, pumps, air conditioning or door strikes in access control applications. Each output's function and operating time are programmed from the panel. The board connects to the 4-wire RS485 bus and can be mounted away from the panel: up to 300 m with standard alarm cable or up to 1,200 m with Belden 8723 shielded two-pair twisted cable. It is fully supervised by the panel.
The address is set with a 4-way DIP switch; all boards leave the factory at address 1. No enabling is needed in programming: the panel recognises the board after a power cycle or a bus scan (MENU 6-0-2). To test the wiring, each output can be operated from its own test button on the board, without a keypad, and LEDs show the status of the module and of each output. There is a service keypad connector and a tamper input; if it is not used, fit the supplied jumper.
| 1 | 4 relay outputs. Form C (NO/NC/COM), 2 A @ 24 V DC each. |
|---|---|
| 2 | Remote mounting. On the RS485 bus, up to 1,200 m with Belden 8723. |
| 3 | Test buttons. One per output, to check wiring without a keypad. |
| 4 | LED indicators. Module and individual output status. |
| 5 | Service keypad and tamper. Dedicated connector and tamper input. |
| 6 | Up to 8 boards. On Vision-X, Vision-XIP and MyAlarm-XIP. |
Technical specifications
CM710
| OUTPUTS | |
|---|---|
| Number | 4 relays, Form C (NO/NC/COM) |
| Contact rating | 2 A @ 24 V DC |
| Programming | Function and operating time from the panel |
| CONNECTION | |
| Bus | 4-wire RS485, fully supervised |
| Maximum length | 300 m with alarm cable, 1,200 m with Belden 8723 |
| Address | 4-way DIP switch (factory setting 1) |
| Recognition | Power cycle or bus scan (MENU 6-0-2) |
| ELECTRICAL | |
| Operating voltage | 10.0–14.5 V DC |
| Consumption | 30 mA, up to 200 mA with all relays and LEDs on |
| INPUTS AND INDICATORS | |
| Inputs | Cabinet tamper, output test buttons |
| Connectors | Service keypad |
| Indicators | Module and output status LEDs |
| COMPATIBILITY | |
| Vision-X, Vision-XIP, MyAlarm-XIP | Up to 8 boards |
| Vision-ICON | 1 board |
| Vision-GRAPHIC | Up to 16 boards |
| ENVIRONMENT AND MECHANICAL | |
| Operating temperature | −30 to +55 °C |
| Humidity | 5–85% at 30 °C, non-condensing |
| Dimensions (W × D × H) | 115 × 86 × 30 mm |
Documents
3 PDF files · English and Greek
| Type | TITLE | LANGUAGE | FORMAT | Open |
|---|---|---|---|---|
| Installation manualCM710 - Installation manual EN.pdf | English | PDF · 3.9 MB | Download the file Installation manual | |
| DatasheetCM710 - Datasheet EN.pdf | English | PDF · 1.5 MB | Download the file Datasheet | |
| DatasheetCM710 - Datasheet GR.pdf | Greek | PDF · 0.6 MB | Download the file Datasheet |