Description
Multi-expander on the panel's RS485 bus that combines a 13.8 V / 1 A power supply with battery charging, an 8/16 zone expansion and 4 supervised open-collector outputs on one board.
| Power supply | 13.8 V DC / 1 A, 12 V / 7.2 Ah battery |
|---|---|
| Zones | 8/16 (16 wired with CM707) |
| Outputs | 4 open-collector, 500 mA each |
| Bus | Up to 300 m with standard cable, 1,200 m with Belden 8723 |
| AC input | 16–18 V AC, 24 VA |
| Supervision | Full, by the panel |
Product description
CM705P · Digiflex
Multi-expander on the panel's RS485 bus that combines a 13.8 V / 1 A power supply with battery charging, an 8/16 zone expansion and 4 supervised open-collector outputs on one board.
The CM705P does the job of three boards: a CM720-type power supply, a CM704-type zone expander and an output expander. It is useful when the system has several partitions, because in each area one board gives power, siren and strobe outputs and up to 16 zones. It connects to the encrypted four-wire RS485 bus and the panel recognises it after a power cycle or a bus scan, with no programming needed to enable it. It optionally takes the CM707 plug-on board for 8 more wired zones.
The built-in 13.8 V DC / 1 A supply is fed by a 16–18 V AC / 24 VA transformer and charges a 12 V / 7.2 Ah sealed lead-acid battery. The 6 +12 V terminals give 1 A in total for detectors, keypads and other expanders, with a resettable fuse, and the COMM+ terminal up to 2.5 A for the outputs. Transformer, battery and enclosure are not included; the board fits the MW700, MW710, MW720 or MW730 enclosures and takes two module spaces.
The 4 open-collector outputs give up to 500 mA (−) each, are protected against overload and short circuit and are supervised for short and open circuit, so they can also drive siren speakers. The address is set with a DIP switch and the board takes the same address for zones, outputs and power. Four LEDs show AC mains, battery, overload and status. The +Loop terminal is only for bus termination and carries no voltage.
| 1 | Three expanders in one. 1 A power, 8/16 zones and 4 open-collector outputs. |
|---|---|
| 2 | Supervised outputs. 500 mA each, overload and short-circuit protected. |
| 3 | Battery-backed supply. 13.8 V / 1 A with 12 V / 7.2 Ah battery charging. |
| 4 | Simpler wiring. 6 +12 V terminals for detectors and keypads, with resettable fuse. |
| 5 | Expand with CM707. Optional plug-on board for 16 wired zones in total. |
| 6 | Service keypad. Service keypad connector and tamper input. |
Technical specifications
CM705P
| ZONES AND OUTPUTS | |
|---|---|
| Zones | 8 (single EOL or alarm + tamper) or 16 (zone doubling); 16 wired with CM707 |
| EOL options | Up to 15 values, one setting for the whole system |
| Zone names | Up to 20 characters |
| Outputs | 4 open-collector, up to 500 mA (−) each |
| Output protection | Overload and short circuit; supervised for short and open circuit |
| POWER | |
| AC input | 16–18 V AC, 50–60 Hz, 24 VA (transformer not included) |
| Battery | Sealed lead-acid 12 V / 7.2 Ah (not included) |
| Peripheral power | +12 V, 1 A in total, 6 terminals, PTC fuse |
| COMM+ output | Up to 2.5 A for the outputs, PTC fuse |
| Board current | Up to 90 mA at 10.0–14.5 V DC |
| Indicators | AC mains, battery, overload and status LEDs |
| BUS | |
| Connection | Encrypted RS485 bus, 4 wires |
| Length | Up to 300 m with standard cable, 1,200 m with Belden 8723 |
| Address | DIP switch |
| Supervision | Full, by the panel, anti-substitution |
| +Loop | For wiring termination only, no voltage |
| INSTALLATION | |
| Required | Transformer, battery and enclosure |
| Enclosure | MW700, MW710, MW720 or MW730 (2 spaces) |
| Connectors | Service keypad and tamper input |
| Compatible panels | Vision-X, Vision-XIP, MyAlarm-XIP, MyAlarm 816, TITAN |
| Board dimensions | 235 × 85 × 40 mm |
| Operating temperature | −30 to +55 °C |
| Operating humidity | 5–85% at 30 °C, non-condensing |
Documents
3 PDF files · English and Greek
| Type | TITLE | LANGUAGE | FORMAT | Open |
|---|---|---|---|---|
| Installation manualCM705P - Installation manual EN.pdf | English | PDF · 2.7 MB | Download the file Installation manual | |
| DatasheetCM705P - Datasheet EN.pdf | English | PDF · 3.5 MB | Download the file Datasheet | |
| DatasheetCM705P - Datasheet GR.pdf | Greek | PDF · 0.8 MB | Download the file Datasheet |