CM705P – Multi-expansion board (power, outputs, zones)

Description

Product description

CM705P · Digiflex

Multi-expander on the panel's RS485 bus that combines a 13.8 V / 1 A power supply with battery charging, an 8/16 zone expansion and 4 supervised open-collector outputs on one board.

The CM705P does the job of three boards: a CM720-type power supply, a CM704-type zone expander and an output expander. It is useful when the system has several partitions, because in each area one board gives power, siren and strobe outputs and up to 16 zones. It connects to the encrypted four-wire RS485 bus and the panel recognises it after a power cycle or a bus scan, with no programming needed to enable it. It optionally takes the CM707 plug-on board for 8 more wired zones.

The built-in 13.8 V DC / 1 A supply is fed by a 16–18 V AC / 24 VA transformer and charges a 12 V / 7.2 Ah sealed lead-acid battery. The 6 +12 V terminals give 1 A in total for detectors, keypads and other expanders, with a resettable fuse, and the COMM+ terminal up to 2.5 A for the outputs. Transformer, battery and enclosure are not included; the board fits the MW700, MW710, MW720 or MW730 enclosures and takes two module spaces.

The 4 open-collector outputs give up to 500 mA (−) each, are protected against overload and short circuit and are supervised for short and open circuit, so they can also drive siren speakers. The address is set with a DIP switch and the board takes the same address for zones, outputs and power. Four LEDs show AC mains, battery, overload and status. The +Loop terminal is only for bus termination and carries no voltage.

STANDARD FUNCTIONS
1Three expanders in one. 1 A power, 8/16 zones and 4 open-collector outputs.
2Supervised outputs. 500 mA each, overload and short-circuit protected.
3Battery-backed supply. 13.8 V / 1 A with 12 V / 7.2 Ah battery charging.
4Simpler wiring. 6 +12 V terminals for detectors and keypads, with resettable fuse.
5Expand with CM707. Optional plug-on board for 16 wired zones in total.
6Service keypad. Service keypad connector and tamper input.

Technical specifications

CM705P

ZONES AND OUTPUTS
Zones8 (single EOL or alarm + tamper) or 16 (zone doubling); 16 wired with CM707
EOL optionsUp to 15 values, one setting for the whole system
Zone namesUp to 20 characters
Outputs4 open-collector, up to 500 mA (−) each
Output protectionOverload and short circuit; supervised for short and open circuit
POWER
AC input16–18 V AC, 50–60 Hz, 24 VA (transformer not included)
BatterySealed lead-acid 12 V / 7.2 Ah (not included)
Peripheral power+12 V, 1 A in total, 6 terminals, PTC fuse
COMM+ outputUp to 2.5 A for the outputs, PTC fuse
Board currentUp to 90 mA at 10.0–14.5 V DC
IndicatorsAC mains, battery, overload and status LEDs
BUS
ConnectionEncrypted RS485 bus, 4 wires
LengthUp to 300 m with standard cable, 1,200 m with Belden 8723
AddressDIP switch
SupervisionFull, by the panel, anti-substitution
+LoopFor wiring termination only, no voltage
INSTALLATION
RequiredTransformer, battery and enclosure
EnclosureMW700, MW710, MW720 or MW730 (2 spaces)
ConnectorsService keypad and tamper input
Compatible panelsVision-X, Vision-XIP, MyAlarm-XIP, MyAlarm 816, TITAN
Board dimensions235 × 85 × 40 mm
Operating temperature−30 to +55 °C
Operating humidity5–85% at 30 °C, non-condensing

Documents

3 PDF files · English and Greek

TypeTITLELANGUAGEFORMATOpen
PDFInstallation manualCM705P - Installation manual EN.pdfEnglishPDF · 2.7 MBDownload the file Installation manual
PDFDatasheetCM705P - Datasheet EN.pdfEnglishPDF · 3.5 MBDownload the file Datasheet
PDFDatasheetCM705P - Datasheet GR.pdfGreekPDF · 0.8 MBDownload the file Datasheet