Tags:
Digiflex
, Vision-XIP
, CC714PGR
, κεντρική μονάδα συναγερμού
, πίνακας συναγερμού
, alarm panel
, IP
, MyAlarm
, iFob Control
Description
Professional security & automation system with IP reporting (CSV IP, SIA IP): 8 zones (16 with zone doubling), expandable to 144, 8 partitions, 990 users and 16 access control doors.
| Zones | 8 (16 doubled), up to 144 |
|---|---|
| Partitions | 8 |
| Users | 990 |
| Access control doors | 16 |
| Keypads / readers | Up to 16 |
| Communication | CSV IP, SIA IP (Ethernet/WiFi, GPRS) |
Product description
CC714PGR · Digiflex
Vision-XIP Alarm & Access Control Panel
Professional Security & Automation System
| 1 | Origin & Certification: Designed and manufactured in Australia to the international quality assurance standard AS/NZS ISO9001. |
|---|---|
| 2 | Zone Capacity: 8 base zones (16 with zone doubling), expandable to 144 (wired or wireless). |
| 3 | Partitions: 8 fully independent partitions. |
| 4 | Outputs: 4 Open Collector (O.C.) digital outputs and 1 relay output (NC/C/NO) on board, expandable to 37 outputs. |
| 5 | User Management: Up to 990 users by PIN code (1–8 digits), wireless remote control (RF), proximity fob or biometric reader (fingerprint). |
| 6 | Duress Function: A dedicated duress code can be set per user. |
| 7 | Keypads & Readers: Up to 16 keypads/readers. Cable runs up to 300 m (standard cable) or up to 1,200 m (Belden 8723 shielded cable). |
| 8 | LAN Communication: Advanced RS-485 LAN with CRC-based data encryption for maximum speed and security. |
| 9 | Network Security: RS-485 LAN lock function that protects against unwanted loss or replacement of peripheral devices (keypads, expanders). |
| 10 | LAN over IP: The RS-485 LAN can be extended/carried over an Ethernet network with the CM430S module (RS485-to-Ethernet). |
| 1 | Door Control: Up to 16 controlled access doors (Access Control). |
|---|---|
| 2 | Schedules: 16 independent time schedules (with 4 time periods each) for:
|
| 3 | Macros: Up to 8 programmable rules/actions (macros) for advanced automation. |
| 4 | Audible Warning: Programmable audible warning time before automatic arming. |
| 5 | Partition Supervision: An inactivity signal can be sent to the Alarm Receiving Centre (ARC) if a partition stays disarmed longer than the set time. |
| 1 | Greek Menu: Full Greek language support on keypads and management software. |
|---|---|
| 2 | Custom Naming: Full naming of users, zones, outputs, arming modes, partitions, keypads, card readers, communication modules and schedules. |
| 3 | Built-in Proximity Reader: Keypads with a built-in proximity reader for fast arming (Full, Perimeter, Part). |
| 4 | Display & Indications: Adjustable contrast, brightness and buzzer volume. Shows date/time, temperature, partition status and system icons. |
| 5 | Emergency Keys: Dedicated Panic, Fire and Medical buttons. |
| 6 | Quick Arming: Quick Arm and perimeter arming with a single key press. |
| 7 | Keypad Assignment: A keypad can be locked to a specific partition (Home Area). |
| 8 | Event Memory: Log of 2,000 events with time and date, viewable directly on the graphic keypad. |
| 9 | Outdoor Peripherals: Weatherproof keypads and card readers available. |
| 10 | Chime Function: Entry notification (Chime Alarm) from the keypad buzzer when a zone opens in a disarmed partition. |
| 11 | Automatic Time: Automatic daylight saving time adjustment. |
| 1 | Zone Types & Settings: 15 different zone types. Programmable end-of-line resistor value (EOL) or no-resistor operation (No EOL), per zone or globally. |
|---|---|
| 2 | Wiring Tolerance: ±20% value tolerance on zones for smooth operation over long cable runs. |
| 3 | Forced Arming: Automatic bypass of faulty zones on arming, per user and/or zone. |
| 4 | False Alarm Protection: Adjustable pulse count per zone and Pre-Delay function (the time a zone must stay open before an alarm is triggered). |
| 5 | N/O Contacts: Zones can be set to Normally Open (N/O) operation. |
| 6 | Detector Supervision: Automatic detector inactivity check while the system is disarmed, with a notification to the ARC and an indication on the keypad. |
| 7 | Entry Times: 2 independent entry delay times per partition (Delay 1 / Delay 2). |
| 1 | Electronic Fuses: Protection against overvoltage, overload and short circuit on the siren, RS-485 LAN, peripheral and battery lines. |
|---|---|
| 2 | Lightning Protection: Surge protection up to 3,000 V on the control panel, zones, outputs and peripherals. |
| 3 | Supervised Outputs: 4 fully protected and supervised digital outputs (D.O.) on the control panel. |
| 4 | Tamper Tolerance: If a peripheral device (e.g. siren, keypad or detector) is destroyed by a cut, short circuit or high voltage, the control panel keeps working and reports the fault to the ARC. |
| 5 | Smart Lock-out: Automatic smart lock-out of the siren and the communicator. |
| 1 | Communication Protocols: Supports CSV IP and SIA IP (over Ethernet/WiFi, GPRS, GPRS/VPN). |
|---|---|
| 2 | Multiple Receivers: Reports to 2 different receivers/receiving centres. |
| 3 | Failed Report Handling: Failed reports can be cancelled automatically and logged in the history once all attempts are used up. |
| 4 | Smart Mobile App & Cloud:
|
| 1 | Fire Detection: Full support for true fire detection zones. |
|---|---|
| 2 | Elderly / Care Monitoring: Dedicated inactivity detection while the system is disarmed or perimeter armed, automatically sending a Medical alarm to the ARC and activating an output. |
| 3 | Wireless Technology:
|
| 4 | Service Reminder: Programmable service reminder on the keypad display after a set period. |
Technical specifications
CC714PGR
| ZONES | |
|---|---|
| Zones | 8, or 16 with zone doubling |
| Zone expansion | Up to 144, wired or wireless |
| Zone types | 15 |
| Zone tolerance | ±20%, for long cable runs |
| End-of-line resistor (EOL) | Programmable value; no-EOL mode per zone or for all zones |
| Zone options | Pulse count, pre-delay, normally open (N/O) per zone |
| Entry delays | 2 per partition |
| Automatic bypass | Per user or per zone |
| Detector supervision | Zone inactivity while disarmed: signal to the receiving centre and message on the keypad |
| PARTITIONS AND ARMING | |
| Partitions | 8, fully independent |
| Quick arm | One key, including perimeter arming |
| Auto-arm warning | Audible, with programmable duration |
| Partition supervision | Inactivity signal to the receiving centre when a partition stays disarmed longer than the set time |
| Keypad lock | Per partition |
| Chime | The keypad buzzer sounds when a chime zone opens while its partition is disarmed |
| USERS AND ACCESS | |
| Users | 990 |
| User credentials | PIN (1–8 digits), remote control, proximity, fingerprint |
| Duress code | Per user |
| Arm / disarm reports | Per user and per partition |
| Access control doors | 16 |
| Schedules | 16 weekly, with 4 time periods each |
| Schedule use | Automatic partition arming/disarming, door lock/unlock, user access by day and time, output control |
| Macros | Up to 8 (rules and actions) |
| OUTPUTS | |
| On-board outputs | 4 open-collector digital + 1 relay (NC, C, NO) |
| Output expansion | Up to 37 in total |
| Output triggers | 75 events, 15 polarity options |
| Protected outputs | The 4 on-board digital outputs, supervised |
| Auxiliary power | 3 outputs with electronic fuses, for detectors, keypads and sirens |
| Low battery | Outputs can be disabled so reports still go out |
| PERIPHERALS AND BUS | |
| Keypads / card readers | Up to 16, including outdoor models |
| RS485 bus | CRC data encryption; bus lock against peripheral substitution |
| Bus length | Up to 300 m with multi-core alarm cable, up to 1,200 m with Belden 8723 shielded twisted pair |
| Bus over Ethernet | With the CM430S converter |
| Wireless | Battery and signal checks; devices are stored in the panel memory, not the receiver |
| Remote control | Two-way RF110 |
| COMMUNICATION | |
| Telephone dialler | No (no PSTN answering either) |
| Receiving centre receivers | 2 |
| Reporting formats | SIA IP, CSV IP |
| Networks | Ethernet/Wi-Fi, GPRS, GPRS/VPN |
| Compatible modules | CP737 Wi-Fi keypad, CM751, CM747, CM369, MY747, MY369 |
| MyAlarm | Via the European MyAlarm Server over VPN (CSV IP, SIA IP) |
| App | iFob Control for iOS and Android |
| PROTECTION AND SPECIAL FUNCTIONS | |
| Electronic fuses | Siren, RS485 bus, peripherals, battery: overvoltage, overcurrent, short circuit |
| Surge protection | Up to 3,000 V on board, zones, outputs and peripherals |
| Surge damage | The system keeps working and reports the fault to the receiving centre |
| Smart lock | Siren and communicator |
| Fire detection | Yes |
| Elderly monitoring | Zone inactivity while disarmed or perimeter armed: medical alarm to the receiving centre and an output switches on |
| GENERAL | |
| Event log | 2,000 events with date and time, readable on a graphic keypad |
| Keypad | Greek; date, time, temperature, partition status; panic, fire and medical buttons |
| Custom names | Users, zones, outputs, partitions, keypads, readers, communication modules, schedules |
| Programming software | VisionLink, no extra hardware |
| Daylight saving | Automatic |
| Service reminder | Keypad message after a set interval |
| Manufacturing standard | AS/NZS ISO 9001 (Australia) |
| In the box | Control panel and wiring accessories |
Documents
6 PDF files · English and Greek
| Type | TITLE | LANGUAGE | FORMAT | Open |
|---|---|---|---|---|
| User manualCC714PGR - User manual EN.pdf | English | PDF · 1.2 MB | Download the file User manual | |
| Installation manualCC714PGR - Installation manual EN.pdf | English | PDF · 2.8 MB | Download the file Installation manual | |
| Installer reference guideCC714PGR - Installer reference guide EN.pdf | English | PDF · 1.4 MB | Download the file Installer reference guide | |
| User manualCC714PGR - User manual GR.pdf | Greek | PDF · 2.8 MB | Download the file User manual | |
| Menu quick referenceCC714PGR - Menu quick reference GR.pdf | Greek | PDF · 0.3 MB | Download the file Menu quick reference | |
| Comparison tableCC714PGR - Comparison table GR.pdf | Greek | PDF · 0.1 MB | Download the file Comparison table |