CC716PGR – MyAlarm-XIP alarm control panel

Description

Product description

CC716PGR · Digiflex

MyAlarm-XIP alarm control panel with the features of the Vision-XIP, communicating over MyAlarm IP only: 8 zones (16 doubled), expandable to 144, with 8 partitions and 990 users.

MyAlarm-XIP has the features of the Vision-XIP and is designed and manufactured in Australia to AS/NZS ISO 9001. It supports 8 fully independent partitions, 990 users, 16 access control doors, 8 macros and up to 16 keypads or card readers on the RS485 bus, which is protected by CRC encryption and a peripheral lock.

All communication goes through MyAlarm, which also carries the reports to the alarm receiving centre in SIA IP, CSV IP or Contact ID. It connects through the CP737 Wi-Fi keypad or the CM747 / MY747 modules, or optionally CM751 / MY369, and you manage it remotely with the iFob Control app on iOS and Android.

The keypad and the VisionLink programming software both support Greek. The box contains the control panel and the wiring accessories; the keypad is sold separately.

STANDARD FUNCTIONS
1Zones and partitions. 8 zones, or 16 doubled, up to 144 wired or wireless, 15 zone types, in 8 independent partitions.
2Users and access control. 990 users with PIN, remote control, proximity or fingerprint, and 16 access control doors.
3Schedules and macros. 16 weekly schedules with 4 time periods and 8 macros for automatic arming, doors and outputs.
4MyAlarm IP only. Alarm receiving centre reports through MyAlarm, in SIA IP, CSV IP or Contact ID.
5Connection options. CP737 Wi-Fi keypad, CM747 / MY747 modules, or optionally CM751 / MY369.
6Protection. Electronic fuses on siren, bus, peripherals and battery, and surge protection up to 3,000 V.

Technical specifications

CC716PGR

ZONES
Zones8, or 16 with zone doubling
Zone expansionUp to 144, wired or wireless
Zone types15
Zone tolerance±20%, for long cable runs
End-of-line resistor (EOL)Programmable value; no-EOL mode per zone or for all zones
Zone optionsPulse count, pre-delay, normally open (N/O) per zone
Entry delays2 per partition
Automatic bypassPer user or per zone
Detector supervisionZone inactivity while disarmed: signal to the receiving centre and message on the keypad
PARTITIONS AND ARMING
Partitions8, fully independent
Quick armOne key, including perimeter arming
Auto-arm warningAudible, with programmable duration
Partition supervisionInactivity signal to the receiving centre when a partition stays disarmed longer than the set time
Keypad lockPer partition
ChimeThe keypad buzzer sounds when a chime zone opens while its partition is disarmed
USERS AND ACCESS
Users990
User credentialsPIN (1–8 digits), remote control, proximity, fingerprint
Duress codePer user
Arm / disarm reportsPer user and per partition
Access control doors16
Schedules16 weekly, with 4 time periods each
Schedule useAutomatic partition arming/disarming, door lock/unlock, user access by day and time, output control
MacrosUp to 8 (rules and actions)
OUTPUTS
On-board outputs4 open-collector digital + 1 relay (NC, C, NO)
Output expansionUp to 37
Output triggers75 events, 15 polarity options
Protected outputsThe 4 on-board digital outputs, supervised
Auxiliary power3 outputs with electronic fuses, for detectors, keypads and sirens
Low batteryOutputs can be disabled so reports still go out
PERIPHERALS AND BUS
Keypads / card readersUp to 16, including outdoor models
RS485 busCRC data encryption; bus lock against peripheral substitution
Bus lengthUp to 300 m with multi-core alarm cable, up to 1,200 m with Belden 8723 shielded twisted pair
Bus over EthernetWith the CM430S converter
WirelessBattery and signal checks; devices are stored in the panel memory, not the receiver
Remote controlTwo-way RF110
COMMUNICATION
ProtocolMyAlarm IP only
Alarm receiving centre reportsThrough MyAlarm: SIA IP, CSV IP, Contact ID
MyAlarm connectionCP737 Wi-Fi keypad or CM747 / MY747 modules
OptionalCM751 / MY369
Telephone diallerNo
AppiFob Control for iOS and Android
PROTECTION AND SPECIAL FUNCTIONS
Electronic fusesSiren, RS485 bus, peripherals, battery: overvoltage, overcurrent, short circuit
Surge protectionUp to 3,000 V on board, zones, outputs and peripherals
Surge damageThe system keeps working and reports the fault to the receiving centre
Smart lockSiren
Fire detectionYes
Elderly monitoringZone inactivity while disarmed or perimeter armed: medical alarm to the receiving centre and an output switches on
GENERAL
Event log2,000 events with date and time, readable on a graphic keypad
KeypadGreek; date, time, temperature, partition status; panic, fire and medical buttons
Custom namesUsers, zones, outputs, partitions, keypads, readers, communication modules, schedules
Programming softwareVisionLink, no extra hardware
Daylight savingAutomatic
Service reminderKeypad message after a set interval
Manufacturing standardAS/NZS ISO 9001 (Australia)
In the boxControl panel and wiring accessories (no keypad)

Documents

4 PDF files · English and Greek

TypeTITLELANGUAGEFORMATOpen
PDFUser manual (Vision-XIP)CC716PGR - User manual EN (Vision-XIP).pdfEnglishPDF · 1.2 MBDownload the file User manual (Vision-XIP)
PDFInstallation manual (Vision-XIP)CC716PGR - Installation manual EN (Vision-XIP).pdfEnglishPDF · 2.8 MBDownload the file Installation manual (Vision-XIP)
PDFUser manual (Vision-XIP)CC716PGR - User manual GR (Vision-XIP).pdfGreekPDF · 2.8 MBDownload the file User manual (Vision-XIP)
PDFComparison table (Vision-X Vision-XIP MyAlarm-XIP)CC716PGR - Comparison table GR (Vision-X Vision-XIP MyAlarm-XIP).pdfGreekPDF · 0.1 MBDownload the file Comparison table (Vision-X Vision-XIP MyAlarm-XIP)