701Server Επιλογή Τύπου Controller LAN

701ServerSQL LANbased
 

 

 

No. LAN Model No.
10.2 version and before
LAN Model No.
10.2 version and after
Correspondent Hardware Model No. Communication Interface Port Active Communication Mode (Non-Polling)
1. TCP_IO TCP_IO

IP Based I/O Module

- AR-727-CM-IO- 0804M
- AR-401-IO-0808R-U2

TCP/IP 1601

YES (required additional setting of

Message Server IP point to 701ServerSQL's

Local TCP Link Address & TCP Port)

2. RS485_IO RS485_IO

RS485 I/O Module

- AR-401-IO-0016R
- AR-401-IO-1709R
- AR-403-IO Series

RS485
(via AR-321-CM converter)
1601 X
3.

881/837/331E&EF

/82xEv5/721

/725Ev2/727/327Hv5

327E/3xxE/

7xxE/8xxE/716Ev5

All Enterprise Series Controller (E Series)

- AR-725-E
- AR-331E&EF
- AR-837-E&EF
- AR-727-E
- AR-327-E

 Control Panel

-AR-716-E16

Enterprise Series Controller(Old Version)

- AR-881-EF
- AR-829-EV5

TCP/IP
(if onboard TCP/IP module)
1621

YES (required additional setting

of Message Server IP point to

701ServerSQL's Local TCP Link

Address & TCP Port)

TCP/IP
(via AR-727-CM converter)
CH1 1621
CH2 1623
X
RS485
(via AR-321-CM converter)
  X
4. 721E_1024 721E_1024

Dual WG control panel

- AR-716-E02

RS485
(via AR-321-CM converter)
  X
5.

3K 321/331/

725/888H

3K 321/331/

725/888H

Home Series (H Series) controller that support 3000 user interface

- AR-321H
- AR-331-H
- AR-725-H
- AR-888-H

TCP/IP
(via AR-727-CM converter)
CH1 1621
CH2 1623
X
RS485
(via AR-321-CM converter)
  X
6. 821EV 821EV

Controller
- AR-821-EV

  

TCP/IP
(via AR-727-CM converter)
CH1 1621
CH2 1623
X
RS485
(via AR-321-CM converter)
  X
7. 821EF V9 821EF V9

Controller
- AR-821-EF

  

TCP/IP
(via AR-727-CM converter)
CH1 1621
CH2 1623
X
RS485
(via AR-321-CM converter)
  X
8. 716E V3/Ei 716E V3/Ei

Control Panel

- AR-716-E18

TCP/IP 1621  
RS485   X
9. 829E V3 829E V3

Controller
- AR-829-H

    

RS485
(via AR-321-CM converter)
  X
10. 727/747 H V3 727/747 H V3

Controller
- AR-327-H
- AR-727-H
- AR-747-H

RS485
(via AR-321-CM converter)
  X
11.

323D/321&888W/721

/757/737/723/101H V3

101H/323D/321&888W

/721/723/757

Home Series (H Series) controller that support 1000 user interface

- AR-101-H
- AR-323D
- AR-888-W
- AR-721-H
- AR-723-H
- AR-757-H

Controller (Old version)
- AR-757-H
- AR-321W

TCP/IP
(via AR-727-CM converter)
CH1 1621
CH2 1623
X
RS485
(via AR-321-CM converter)
  X
12. 829E Old 829E Old

Controller (Old version)
- AR-829-E

    

RS485
(via AR-321-CM converter)
  X

 

Note : Active Communication Mode (Non-Polling) only available for Enterprise Series (E Series) Controller and Control Panel AR-716-E16 with TCP/IP Module on-board